Filter Results By:

Products

Applications

Manufacturers

Antenna Measurement

characterizes an antenna.

See Also: Antenna Test, OTA, Dip Meters


Showing results: 76 - 90 of 179 items found.

  • Plane Wave Converter

    PWC200 - Rohde & Schwarz GmbH & Co. KG

    The R&S®PWC200 Plane Wave Converter is a bidirectional array of 156 wideband Vivaldi antennas placed in the radiating near field of the device under test (DUT). The phased antenna array can form planar waves inside a specified quiet zone within the radiating near field of the 5G massive MIMO base station for realtime radiated power and transceiver measurements (EVM, ACLR, SEM, etc.).

  • SignalPROFILER

    E7042B and E7062B - Deviser Instruments

    The SignalPROFILER combines the power and functionality of cable and antenna system analysis, fiber inspection, spectrum analysis, cellular signal demodulation, interference analysis, signal coverage mapping and RF/Optical power measurements in a single instrument.

  • Biconical Antennas

    Schwarzbeck Mess Elektronik

    Biconical Antennas have dipole like characteristics (e.g. circular directional pattern in the H-plane,"8"-shaped in the E-plane, fixed phase center, comparable gain), with an enormous wide bandwidth achieved by the double cone elements. One of the earliest and worldwide most popular biconical antenna designs is the BBA 9106 with balun VHA 9103 B. During the last years a growing need for expanded frequency ranges arised, which led to the design of biconical antennas reaching down to frequencies of 20 MHz and up to 18 GHz and above. A further increase of bandwidth was achieved with qualified 4:1 baluns, providing a typical gain increase of approx. 6 dB at the lower frequency range. The biconical elements can be mounted and dismounted within a few seconds providing perfect contact repeatability thanks to special clamping fixtures. A small wrench made of insulating material is supplied with the balun, it is tied to the balun head and thus always available whenever needed. Biconical antennas can be used for many applications, in which half-wave dipoles have been used traditionally. An enormous reduction of measurement time can be achieved, because the time consuming tuning of the antenna elements to the half wavelength is not needed, an important condition for sweeped broadband measurements. In typical dipole applications several discrete frequencies are measured, in contrast the biconical antenna allows continuous sweeps, where site anomalies are discovered much easier.

  • Tapered Anechoic Chamber

    Cuming-Lehman Chambers

    It’s nearly impossible to perform VHF/UHF measurements in a rectangular chamber. In the 1960’s Emerson determined that tapering one end of an Anechoic Chamber would cause the chamber to act like an indoor ground reflection range.Tapered Chambers work very well at the lower frequencies. Their design forms a uniform illumination across the test region. The tapered end of the chamber forces the wall images close together forming a source antenna array. Tapered Chambers are usually a less expensive option compared to rectangular antenna measurement chambers or compact ranges.

  • Measuring Small Antennas

    MegiQ BV

    If you have a small PCB with a small antenna you can't use a thick cable and a large connector. Not only is this impractical (how to connect the connector?) but the metal bulk will also affect the antenna and grounding properties of your PCB. The measurement will be useless. MegiQ promotes the use of the small and popular UFL connector and its associated cables. The UFL socket fits on almost any PCB and it can be improvised on a board without a UFL footprint.

  • 1-Port 14 GHz Analyzer

    R140 - Copper Mountain Technologies

    R140 Vector Network Analyzer (cable and antenna analyzer) delivers lab grade performance in a handheld device. This patented (US Patent 9,291,657) analyzer can be connected directly to the antenna or other DUT without the need for a test cable, eliminating measurement uncertainties inherent to cables. Resulting in highly dependable performance and calibration stability. The 1-port VNA comes with all the features engineers have come to expect included standard in our software.

  • 1-Port 18 GHz Analyzer

    R180 - Copper Mountain Technologies

    R180 Vector Network Analyzer (cable and antenna analyzer) delivers lab grade performance in a handheld device. This patented (US Patent 9,291,657) analyzer can be connected directly to the antenna or other DUT without the need for a test cable, eliminating measurement uncertainties inherent to cables. Resulting in highly dependable performance and calibration stability. The 1-port VNA comes with all the features engineers have come to expect included standard in our software.

  • 1-Port 6 GHz Analyzer

    R60 - Copper Mountain Technologies

    R60 Vector Network Analyzer (cable and antenna analyzer) delivers lab grade performance in a handheld device. This patented (US Patent 9,291,657) analyzer can be connected directly to the antenna or other DUT without the need for a test cable, eliminating measurement uncertainties inherent to cables. Resulting in highly dependable performance and calibration stability. The 1-Port VNA comes with all the features engineers have come to expect included standard in our software.

  • Antenna Analyzer

    K6BEZ - HamRadio 360

    The K6BEZ antenna analyzer will provide VSWR measurements for any antenna from 1 to 30 MHz. Frequency and VSWR is shown on the built in LCD display. Data can optionally be sent over the USB cable to a PC running a program that will plot the VSWR on a graphical window display. The analyzer can be programmed to scan any sub band and has built in ranges for 160m, 80m, 60m, 40m, 30m, 20m, 17m, 15m, 12m, 10m.

  • Antenna Analyzer

    iP60z - iPortable

    The new iP60z iPortable™ Antenna SWR Analyzer is designed for field use. This compact battery powered unit has an easy to read frequency display and measures SWR and impedance in the HF Band and VHF 6 Meter band. The SWR readings quickly show you the actual VSWR measurement and Magnitude of the impedance (Z). This is the easiest way to adjust your portable or base station antenna to be best matched for your radio.

  • Antenna Test System

    ATS1000 - Rohde & Schwarz GmbH & Co. KG

    Offering measurements on active and passive devices - supporting also extreme temperature testing. 5G is all about data, speed and reliability using high frequency millimeter wave bands. The lack of conventional external RF connectors makes 5G antenna characterization challenging. 5G antenna, chipset and UE manufacturers as well as wireless market operators need a viable solution for research, diagnostics and debugging up to type approval.

  • Antenna Test Chamber

    Comtest Engineering bv

    Comtest provides Antenna test ranges fully covered with microwave absorbers for both near-field and far-field measurements. Because we always strive for new solutions, our R&D department developed our ‘Javelin Tip’ polystyrene absorbers. The enhanced material composition and altered shape, lead to improved performance and cleaner working space, enabling you to make high precision antenna testing fast, reliable, and worry-free.

  • Passive Intermodulation Analyzers

    Anritsu Corporation

    The current standard of PIM testing offers a well-known system of two primary carriers and a calculated PIM frequency, which is monitored via a spectrum analyzer. This provides a measurement of the overall linearity of the antenna system and the surrounding environment.

  • Fiber optic active antennas / field probes

    EFS-105 - enprobe GmbH

    The EFS-105 is the first in a family of fiber-optic active antennas & E-field probes. The field distortion caused by the probe head is nearly zero due to the exceptionally small probe head and the all-optical signal transmission and power supply. This gives an invaluable advantage for near field measurements and measurements close to metallic parts.

  • Fixed Terminations

    ZTS Technologies Co., Ltd

    Fixed Terminations absorb RF & microwave energy and are commonly used as dummy loads of antenna and transmitter.They are also used as match ports in many multi-port microwave device such as circulator and directional coupler to make these ports which are not involved in the measurement be terminated in their characteristic impedance in order to ensure an accurate measurement

Get Help